Additel ADT878PC Reference Dry Well Calibrator

Brand: Additel

Model No: ADT878PC

Order Code: ADT878PC

Warranty: 1 Year

Stock Status : 2 - 4 Weeks

Original price 54,790.00 AED - Original price 54,790.00 AED
Original price
54,790.00 AED
54,790.00 AED - 54,790.00 AED
Current price Price : 54,790.00 AED (Including VAT)

We are taking temperature calibration to the next level with the Additel 878 Reference Dry Well Calibrators. If you are looking for the best dry well on the market, then look no further! Additel’s commitment to continuous improvement, quality, and time-saving features is on full display in the ADT878 series. With three models to choose from, ranging from -40 to 700°C, you will find the perfect fit for your calibration needs. The Process Calibrator option adds an external reference input, a two-channel readout for UUTs’s, and a full complement of capabilities to help with everything from measuring temperature sensors to calibrating thermocouples, self-calibrating the Reference Well, and configuring HART transmitters. Each unit comes standard with a large touchscreen display, dual-zone control, and Additel’s commitment to the best customer service in the industry. We are certain that you will be blown away by the outstanding performance of these game-changing Reference Dry Wells.

PROCESS CALIBRATOR OPTION

Each model can be purchased with our Process Calibrator (PC) option. This option combines the many features found in a fully functional HART documenting process calibrator with the reference grade dry well. This option includes the ability to measure a reference PRT, with virtually any connection type, and two devices under test channels that can measure mA, voltage, switch, RTD, or thermocouple. In addition to these measurement functions, this calibrator has the full documenting capability of creating tasks, saving as found and as left results, as well as communicating with HARTsmart transmitters. The process calibrator option also has an onboard full HART communicator which allows users to read, configure, and calibrate HART transmitters. The snapshot feature allows you to capture all information displayed on the screen with the push of a button. This optional add-on allows for data logging of all channels on an auto-step function. By utilizing the reference PRT, you can select to control the dry well set point using the internal sensor or the external reference PRT.

SELF CALIBRATION

We believe using an external reference probe as your standard is the best way to perform your temperature calibration. But we also recognize this method is not always necessary or convenient and depending on the application, using the internal control sensor would be preferred. Traditionally, the internal control sensor has a wide accuracy which can largely be attributed to its long-term drift. We’ve built in a self-calibration feature allowing you to run an automated calibration of the internal control sensor using your external reference. With literally a few selections the calibration will run automatically giving you a fresh, traceable calibration of the control sensor which will improve its accuracy as you will not have to account for its long-term drift when used as the reference.

AUTOMATION FEATURES

Traditionally, dry wells were simply a stable heat source. To enhance the usability of our Reference Dry Wells, we've added automation features enabling you to utilize these amazing devices as a highly stable heat source, the triple point of water maintenance apparatus, and an annealing furnace. Combined with the ADT878-TPW-KIT, the ADT878-160 Reference Dry Well can be used to automatically realize and maintain a triple point of water cell. Traditional methods take time and practice to realize the triple point of water. Additel has now simplified this process with an automatic TPW realization feature. Simply insert the cell and PRT into the Reference Dry Well and run the procedure. The automation in the firmware will alert when the cell is supercooled. Remove the cell and give it a shake and now you can maintain the triple point in the reference well. This is very useful to check the drift of your PRT. For more information, please see our ADT878-TPW-KIT data sheet. When you purchase our 700°C Reference Dry Well, you will find our automatic annealing feature used to anneal PRTs. We have preconfigured annealing procedures that set the temperature annealing time and cool-down rate. This feature, also lets you create your own annealing procedures.